Channel Performance
Tested against international cabling standards
Six Class EA cabling systems from six different market-leading suppliers (3 x U/UTP; 1 x F/UTP; 2 x S/FTP)
Test criteria: ISO/IEC 11801 Ed. 2.1 Class EA channel (including the channel requirements of ANSI/TIA/EIA-568-B.2-10 Cat. 6A).
System 00 failed in the PS ANEXT parameter and also showed a tremendously weak Coupling Attenuation. Therefore it did not qualify for further MICE testing and was taken out of the study.